Journal of vascular surgery, 1 1 2024, Pages S0741-5214(24)00405-1 Intraoperative transit time flow measurement predicts maturation of radiocephalic arteriovenous fistulas. de Winter EP, Wilschut D, Plasmans K, Eefting D, van der Steenhoven T, Putter H, Rotmans J, van der Bogt K

Objective

The arteriovenous fistula (AVF) is the first choice for gaining vascular access for hemodialysis. However, 20% to 50% of AVFs fail within 4 months after creation. Although demographic risk factors have been described, there is little evidence on the intraoperative predictors of AVF maturation failure. The aim of this study was to assess the predictive value of intraoperative transit time flow measurements (TTFMs) on AVF maturation failure.

Methods

In this retrospective cohort study, intraoperative blood flow, measured using TTFM, was compared with AVF maturation after 6 weeks in 55 patients. Owing to its significantly higher prevalence and risk of nonmaturation, the radiocephalic AVF (RCAVF) was the main focus of this study. A recommended cutoff point for high vs low intraoperative blood flow was determined for RCAVFs, using a receiver operating characteristic curve.

Results

The average intraoperative blood flow in RCAVFs was 156 mL/min. Patients with an intraoperative blood flow equal or lower than the determined cutoff point of 160 mL/min, showed a 3.03 times increased risk of AVF maturation failure after 6 weeks, compared with patients with a higher intraoperative blood flow (P < .001).

Conclusions

The intraoperative blood flow in RCAVFs measured by TTFM provides an adequate means of predicting AVF nonmaturation 6 weeks after surgery. For RCAVFs, a cutoff point for intraoperative blood flow of 160 mL/min is recommended for maximum sensitivity and specificity to predict AVF maturation failure after 6 weeks.