Cited 12 times since 2007 (0.7 per year) source: EuropePMC Radiology, Volume 246, Issue 2, 4 1 2007, Pages 394-400 MR imaging of right ventricular function after the Ross procedure for aortic valve replacement: initial experience. Grotenhuis HB, de Roos A, Ottenkamp J, Schoof PH, Vliegen HW, Kroft LJ

Purpose

To prospectively assess right ventricular (RV) function after the Ross procedure by using magnetic resonance (MR) imaging.

Materials and methods

The local ethics committee approved the study and informed consent was obtained from all participants prior to enrollment in the study. Seventeen patients (15 male, two female; mean age +/- standard deviation, 19 years +/- 3.9; imaging performed 8.3 years after surgery +/- 3.2) and 17 matched controls (15 male, two female; mean age +/- standard deviation, 20 years +/- 3.9) were studied by using MR imaging. Standard velocity-encoded and multisection multiphase imaging sequences were used to assess homograft valve function, systolic and diastolic RV function, and RV mass. The two-tailed Mann-Whitney U test and the Spearman rank correlation coefficient were used for statistical analysis.

Results

Minor degrees of homograft stenosis (peak flow velocity between 1.5 and 3.0 m/sec across the homograft valve) were found in 12 of 17 patients but not in controls (P < .001). A larger RV mass was present in Ross patients than in controls (17.0 g/m(2) +/- 4.8 vs 10.9 g/m(2) +/- 5.6, P = .004). In addition, impaired diastolic RV function was found, as shown by a decreased mean tricuspid valve early filling phase-atrial contraction phase (E/A) peak flow velocity ratio (1.56 +/- 0.75 vs 2.05 +/- 0.58, P = .03). Peak flow velocity across the homograft valve correlated with RV mass (r = 0.38, P = .03) and tricuspid valve E/A peak flow velocity ratio (r = 0.39, P = .02). RV systolic function was normal in Ross patients (mean RV ejection fraction, 52% +/- 8 vs 51% +/- 5; P = .74).

Conclusion

RV hypertrophy and RV diastolic dysfunction are frequently observed in patients after the Ross procedure, even in the absence of overt homograft stenosis. RV systolic function is still preserved.

Radiology. 2007 12;246(2):394-400