Cited 2 times since 2023 (3.3 per year) source: EuropePMC Journal of the American College of Cardiology, Volume 82, Issue 16, 1 1 2023, Pages 1598-1610 Flurpiridaz F-18 PET Myocardial Perfusion Imaging in Patients With Suspected Coronary Artery Disease. Maddahi J, Agostini D, Bateman TM, Bax JJ, Beanlands RSB, Berman DS, Dorbala S, Garcia EV, Feldman J, Heller GV, Knuuti JM, Martinez-Clark P, Pelletier-Galarneau M, Shepple B, Tamaki N, Tranquart F, Udelson JE

Background

Flurpiridaz F-18 (flurpiridaz) is a novel positron emission tomography (PET) myocardial perfusion imaging tracer.

Objectives

The purpose of this study was to further assess the diagnostic efficacy and safety of flurpiridaz for the detection and evaluation of coronary artery disease (CAD) defined as ≥50% stenosis by quantitative invasive coronary angiography (ICA).

Methods

In this second phase 3 prospective multicenter clinical study, 730 patients with suspected CAD from 48 clinical sites in the United States, Canada, and Europe were enrolled. Patients underwent 1-day rest/stress flurpiridaz PET and 1- or 2-day rest-stress Tc-99m-labeled single photon emission computed tomography (SPECT) before ICA. PET and SPECT images were read by 3 experts blinded to clinical and ICA data.

Results

A total of 578 patients (age 63.7 ± 9.5 years) were evaluable; 32.5% were women, 52.3% had body mass index ≥30 kg/m2, and 33.6% had diabetes. Flurpiridaz PET met the efficacy endpoints of the study; its sensitivity and specificity were significantly higher than the prespecified threshold value by 2 of the 3 readers. The sensitivity of flurpiridaz PET was higher than SPECT (80.3% vs 68.7%; P = 0.0003) and its specificity was noninferior to SPECT (63.8% vs 61.7%; P = 0.0004). PET area under the receiver-operating characteristic curves were higher than SPECT in the overall population (0.80 vs 0.68; P < 0.001), women, and obese patients (P < 0.001 for both). Flurpiridaz PET was superior to SPECT (P < 0.001) for perfusion defect size/severity evaluation, image quality, diagnostic certainty, and radiation exposure. Flurpiridaz PET was safe and well tolerated.

Conclusions

This second flurpiridaz PET myocardial perfusion imaging trial shows that flurpiridaz has utility as a new tracer for CAD detection, specifically in women and obese patients. (An International Study to Evaluate Diagnostic Efficacy of Flurpiridaz [18F] Injection PET MPI in the Detection of Coronary Artery Disease [CAD]; NCT03354273).

J Am Coll Cardiol. 2023 10;82(16):1598-1610