Virus research, Volume 334, 21 3 2023, Pages 199175 Establishing immunogenicity and safety of needle-free intradermal delivery by nanoporous ceramic skin patch of mRNA SARS-CoV-2 vaccine as a revaccination strategy in healthy volunteers. Prins MLM, Prins C, de Vries JJC, Visser LG, Roukens AHE

Introduction

Nanoporous microneedle arrays (npMNA) are being developed as skin patches for vaccine delivery. As alternative for needle-based immunisation, they may potentially result in higher vaccine acceptance, which is important for future mass vaccination campaigns to control outbreaks, such as COVID-19, and for public vaccination in general. In this study we investigated the safety and immunogenicity of needle-free intradermal delivery of a fractional third or fourth dose of mRNA-1273 vaccine by npMNA.

Methods

This study was an open-label, randomised-controlled, proof-of-concept study. Healthy adults were eligible if they had received a primary immunisation series against SARS-CoV-2 with two doses of mRNA-1273 (Moderna) or BNT162b2 (Pfizer-BioNTech) mRNA vaccine. A history of a COVID-19 infection or booster vaccination with mRNA-1273 or BNT162b2 was allowed if it occurred at least three months before inclusion. Participants were randomised in a 1:1 ratio to receive 20 µg mRNA-1273 vaccine, either through npMNA patch applied on the skin (ID-patch group), or through intramuscular (IM) injection (IM-control group). Primary outcomes were reactogenicity up to two weeks after vaccination, and fold-increase of SARS-CoV-2 spike S1-specific IgG antibodies 14 days post-vaccination.

Results

In April 2022, 20 participants were enroled. The geometric mean concentration (GMC) did not increase in the ID-patch group after vaccination, in contrast to the IM-control group (GMC was 1,006 BAU/mL (95% CI 599-1,689), 3,855 (2,800-5,306), and 3,513 (2,554-4,833) at day 1, 15 and 29, respectively). In addition, SARS-CoV-2-specific T cell responses were lower after ID vaccination through npMNA.

Conclusion

Needle-free delivery of 20 µg mRNA-1273 vaccine by npMNA failed to induce antibody and T cell responses. As this is a potentially very useful vaccination method, it is important to determine which adjustments are needed to make this npMNA successful. CLINICAL TRIAL REGISTRY (ON CLINICALTRIAL.GOV): NCT05315362.