Cited 3 times since 2020 (0.7 per year) source: EuropePMC European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery, Volume 60, Issue 1, 21 3 2020, Pages 49-55 Editor's Choice - Nationwide Analysis of Patients Undergoing Iliac Artery Aneurysm Repair in the Netherlands. Jalalzadeh H, Indrakusuma R, Koelemay MJW, Balm R, Collaborators, Van den Akker LH, Van den Akker PJ, Akkersdijk GJ, Akkersdijk GP, Akkersdijk WL, van Andringa de Kempenaer MG, Arts CH, Avontuur JA, Baal JG, Bakker OJ, Balm R, Barendregt WB, Bender MH, Bendermacher BL, van den Berg M, Berger P, Beuk RJ, Blankensteijn JD, Bleker RJ, Bockel JH, Bodegom ME, Bogt KE, Boll AP, Booster MH, Borger van der Burg BL, de Borst GJ, Bos-van Rossum WT, Bosma J, Botman JM, Bouwman LH, Breek JC, Brehm V, Brinckman MJ, van den Broek TH, Brom HL, de Bruijn MT, de Bruin JL, Brummel P, van Brussel JP, Buijk SE, Buimer MG, Burger DH, Buscher HC, den Butter G, Cancrinus E, Castenmiller PH, Cazander G, Coveliers HM, Cuypers PH, Daemen JH, Dawson I, Derom AF, Dijkema AR, Diks J, Dinkelman MK, Dirven M, Dolmans DE, van Doorn RC, van Dortmont LM, van der Eb MM, Eefting D, van Eijck GJ, Elshof JW, Elsman BH, van der Elst A, van Engeland MI, van Eps RG, Faber MJ, de Fijter WM, Fioole B, Fritschy WM, Geelkerken RH, van Gent WB, Glade GJ,

Objective

The new 2019 guideline of the European Society for Vascular Surgery (ESVS) recommends consideration for elective iliac artery aneurysm (eIAA) repair when the iliac diameter exceeds 3.5 cm, as opposed to 3.0 cm previously. The current study assessed diameters at time of eIAA repair and ruptured IAA (rIAA) repair and compared clinical outcomes after open surgical repair (OSR) and endovascular aneurysm repair (EVAR).

Methods

This retrospective observational study used the nationwide Dutch Surgical Aneurysm Audit (DSAA) registry that includes all patients who undergo aorto-iliac aneurysm repair in the Netherlands. All patients who underwent primary IAA repair between 1 January 2014 and 1 January 2018 were included. Diameters at time of eIAA and rIAA repair were compared in a descriptive fashion. The anatomical location of the IAA was not registered in the registry. Patient characteristics and outcomes of OSR and EVAR were compared with appropriate statistical tests.

Results

The DSAA registry comprised 974 patients who underwent IAA repair. A total of 851 patients were included after exclusion of patients undergoing revision surgery and patients with missing essential variables. eIAA repair was carried out in 713 patients, rIAA repair in 102, and symptomatic IAA repair in 36. OSR was performed in 205, EVAR in 618, and hybrid repairs and conversions in 28. The median maximum IAA diameter at the time of eIAA and rIAA repair was 43 (IQR 38-50) mm and 68 (IQR 58-85) mm, respectively. Mortality was 1.3% (95% CI 0.7-2.4) after eIAA repair and 25.5% (95% CI 18.0-34.7) after rIAA repair. Mortality was not significantly different between the OSR and EVAR subgroups. Elective OSR was associated with significantly more complications than EVAR (intra-operative: 9.8% vs. 3.6%, post-operative: 34.0% vs. 13.8%, respectively).

Conclusion

In the Netherlands, most eIAA repairs are performed at diameters larger than recommended by the ESVS guideline. These findings appear to support the recent increase in the threshold diameter for eIAA repair.