Cited 5 times since 2017 (0.7 per year) source: EuropePMC Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology, Volume 19, Issue 4, 1 1 2017, Pages 560-567 Limited left atrial surgical ablation effectively treats atrial fibrillation but decreases left atrial function. Compier MG, Tops LF, Braun J, Zeppenfeld K, Klautz RJ, Schalij MJ, Trines SA

Aims

Limited left atrial (LA) surgical ablation with bipolar radiofrequency is considered to be an effective procedure for treatment of atrial fibrillation (AF). We studied whether limited LA surgical ablation concomitant to cardiac surgery is able to maintain LA function.

Methods and results

Thirty-six consecutive patients (age 66 ± 12 years, 53% male, 78% persistent AF) scheduled for valve surgery and/or coronary revascularization and concomitant LA surgical ablation were included. Epicardial pulmonary vein isolation (PVI) and additional endo-epicardial lines were performed using bipolar radiofrequency. An age- and gender-matched control group (n = 36, age 66 ± 9 years, 69% male, 81% paroxysmal AF) was selected from patients undergoing concomitant epicardial PVI only. Left atrial dimensions and function were assessed on two-dimensional echocardiography preoperatively and at 3- and 12-month follow-up. Sinus rhythm (SR) maintenance was 67% for limited LA ablation and 81% for PVI at 1-year follow-up (P = 0.18). Left atrial volume decreased from 72 ± 21 to 50 ± 14 mL (31%, P < 0.01) after limited LA ablation and from 65 ± 23 to 56 ± 20 mL (14%, P < 0.01) after PVI. Atrial transport function was restored in 54% of patients in SR after limited LA ablation compared with 100% of patients in SR after PVI. Atrial strain and contraction parameters (LA ejection fraction, A-wave velocity, reservoir function, and strain rate) significantly decreased after limited LA ablation. After PVI, strain and contraction parameters remained unchanged.

Conclusion

Even limited LA ablation decreased LA volume, contraction, transport function, and compliance, indicating both reverse remodelling combined with significant functional deterioration. In contrast, surgical PVI decreased LA volume while function remained unchanged.

Europace. 2017 4;19(4):560-567